Secure monitoring for inverter, battery and site energy.

Production: energy.anxnexora.com

Add Inverter / Energy Device

ShinePhone-style flow: choose the Plant, then the device brand. Normal device onboarding never asks the user for an API key.

No user API key: vendor/provider credentials, when technically required for cloud telemetry, stay protected in ANX backend configuration. Adding a device never unbinds it from the vendor app.

Add Device

Add Growatt Inverter

Choose the Plant, then scan the logger QR or enter its SN and verification/check code. No API key is requested from the device user, and the ShinePhone binding is preserved.

Battery Configuration optional · no fake values
ANX calculates nominal voltage = Cell Count × nominal cell voltage, Total Ah = Cell Ah × Parallel Banks, and kWh = V × Ah ÷ 1000. Other/custom cell types are stored without guessing a cell voltage.
No API key required here. ANX stores the device identity and handles any supported provider/local connection in the backend. Vendor ownership/access controls are still respected.

Add Roman Hybrid Inverter

Enroll the Roman DTU/logger already connected to the customer's Wi-Fi and Solar of Things account. This does not change the DTU Wi-Fi or cloud binding.

Client onboarding only records the DTU identity and Site. Live cloud telemetry starts after Platform Owner links the DTU to an authorized Solar of Things cloud Device ID. The customer Wi-Fi/cloud binding is not changed.
Battery Configuration optional · no fake values
ANX calculates nominal voltage = Cell Count × nominal cell voltage, Total Ah = Cell Ah × Parallel Banks, and kWh = V × Ah ÷ 1000. Other/custom cell types are stored without guessing a cell voltage.

Add Deye Inverter / Logger

Enroll the official Deye device/logger identity without unbinding it from DeyeCloud.

No user API key. Device identity is enrolled from the label/QR. Live telemetry uses a verified ANX backend/local connector when available.
Battery Configuration optional · no fake values
ANX calculates nominal voltage = Cell Count × nominal cell voltage, Total Ah = Cell Ah × Parallel Banks, and kWh = V × Ah ÷ 1000. Other/custom cell types are stored without guessing a cell voltage.

Add Other Inverter Brand

Brand-neutral Plant enrollment. Use the serial number and verification/check code printed on the inverter, logger or QR label. No API key is required.

Identity-first: this registers the device under the Plant without pretending unsupported vendor telemetry is available. ANX can attach a verified cloud/local/gateway connector later.

All Inverter Dongle Setup

Use ANX Direct / Local for a dongle or inverter that exposes a private-LAN TCP service. This mode does not require Growatt/Deye/other cloud API authorization.

Enter a private LAN IP, or scan the server LAN. Auto Detect checks common read-only/local TCP ports.
Read-only safety: ANX only tests TCP/Modbus-TCP connectivity here. It does not guess proprietary register maps or rewrite dongle Wi-Fi/server credentials. Existing vendor-cloud binding is unchanged.
Battery Configuration optional · no fake values
ANX calculates nominal voltage = Cell Count × nominal cell voltage, Total Ah = Cell Ah × Parallel Banks, and kWh = V × Ah ÷ 1000. Other/custom cell types are stored without guessing a cell voltage.

BMS Management

Hardware settings: live JK/JBD values are shown below as read-only. ANX will not write protection thresholds or MOS/balance parameters until the exact model/protocol write path is verified.

Inverter Battery Configuration

Enter the real installed battery-bank specification. ANX never invents capacity when it is not configured or reported by a BMS.

Battery Configuration optional · no fake values
ANX calculates nominal voltage = Cell Count × nominal cell voltage, Total Ah = Cell Ah × Parallel Banks, and kWh = V × Ah ÷ 1000. Other/custom cell types are stored without guessing a cell voltage.
Remaining Ah / stored kWh / runtime are estimates and require live SOC/voltage/load telemetry.